RFC271 - IMP System change notifications

发布: 2007-6-23 14:09 | 作者:   | 来源:   | 查看: 13次 | 进入软件测试论坛讨论

领测软件测试网

   
  Network Working Group Bernard Cosell
RFC# 271 BBN
NIC 7819 3 January 1972
Categories: B.1
Updates: None
Obsoletes: None

IMP System Change Notification
------------------------------

We are planning to install a new version of the IMP System,
version 2514. The new version is scheduled for field installation
Thursday, January 13, 1972 between noon and 1 PM EST, and will require
the assistance of IMP-site personnel at each site.

There were two principal problems with version 2513, both related
to the delay inserted between the time when a Host comes up and the
time when its IMP will accept the second packet from the Host. The
first was that the delay was lengthened to slightly over 40 seconds,
which caused hardware difficulties for some Hosts. The second was
that there was an ambiguity that could make the delay run as long as a
minute and a quarter. On the first point, the delay has been backed
off from 40 seconds to 30 seconds, as it was for IMP systems prior to
2513. On the second point, the ambiguity has been entirely removed.
(Note, however, that BBN Report No. 1822, on page 23, specifies that
the delay may range from 30 to 90 seconds, and that future versions
may require a longer delay.)

In summary, a Host may come alive in one of two ways, corres-
ponding to the two ways in which the Host can go down. If the Host
went down voluntarily (by sending a "Host going down" to the IMP), the
Host indicates his intention to come alive by sending the IMP
something. If the Host went down involuntarily (by dropping his ready
line), the Host indicates his intention to come alive by bringing his
ready line back up. In either case

[Page 1]

the IMP will refuse to accept more than one packet from the Host for
30 seconds after the Host has indicated his intention to come alive.
Notice, however, that the Host must be prepared to accept all messages
from the Network from the instant that he indicates his intention to
come alive.* This particular point seems to have given many Hosts
difficulty in running through their standard initialization
procedures. Don't forget this simple and universal rule, that when
you are telling your IMP that you are alive, you must be prepared to
always take every- thing from the Network whether or not the Network
is taking any- thing from you.

Version 2514 will also incorporate a few other changes, mainly
related to the operation of the NCC. Since the Timeout is, for a
change, being made shorter, and the other modifications are minor,
there should be no appreciable transient with the coming of the new
version.

_______________
*In fact, if the Host does not accept messages from his IMP
pimmediately then the Host may see the IMP's Ready line go down
for 1/4 second sometime during the 30 second waiting period.
This is due to the following set of circumstances:

* The IMP periodically places NOPs on the queue for a
dead Host as part of the process of checking the IMP/Host
interface.

* If a message remains on a Host's queue for 30 seconds
without being taken, the IMP drops its Ready line for
1/4 second in order to clear the interface (see RFC#270).

* The timeout periods for the Host queue and the delay
when the Host comes alive are _not_ synchronized.

If the Host is prepared to see the IMP's Ready line dropped
during the 30-second delay while coming alive, then no harm
will be done if messages from the IMP are not accepted immediately.

BC/jm

[ This RFCwas put into machine readable form for entry ]
[ into the online RFCarchives by BBN Corp. under the ]
[ direction of Alex McKenzie. 12/96 ]

延伸阅读

文章来源于领测软件测试网 https://www.ltesting.net/


关于领测软件测试网 | 领测软件测试网合作伙伴 | 广告服务 | 投稿指南 | 联系我们 | 网站地图 | 友情链接
版权所有(C) 2003-2010 TestAge(领测软件测试网)|领测国际科技(北京)有限公司|软件测试工程师培训网 All Rights Reserved
北京市海淀区中关村南大街9号北京理工科技大厦1402室 京ICP备10010545号-5
技术支持和业务联系:info@testage.com.cn 电话:010-51297073

软件测试 | 领测国际ISTQBISTQB官网TMMiTMMi认证国际软件测试工程师认证领测软件测试网