EVM event name: sys.unix.binlog.hw.scsi
Binary error log events are posted through the binlogd daemon, and
stored in the binary error log file, /var/adm/binary.errlog. This
event is used to report all SCSI device errors, including disk,
tape, HSZ raid events and adapter errors.
Action: Use Compaq Analyze or DECevent to read and analyze the
system error log to determine if a SCSI device may need to be
replaced.
======================================================================
Formatted Message:
SCSI event
Event Data Items:
Event Name : sys.unix.binlog.hw.scsi
Priority : 700
PID : 352
PPID : 1
Event Id : 22686
Timestamp : 16-Mar-2005 10:16:28
Host IP address : 10.2.2.6
Host Name : ccdbs03
User Name : root
Format : SCSI event
Reference : cat:evmexp.cat:300
Variable Items:
subid_class (INT32) = 199
subid_num (INT32) = 0
subid_unit_num (INT32) = 48
subid_type (INT32) = 34
binlog_event (OPAQUE) = [OPAQUE VALUE: 344 bytes]
============================ Translation =============================
Sequence number of error: 1292245096
Time of error entry: 16-Mar-2005 10:16:28
Host name: ccdbs03
SCSI CAM ERROR PACKET
SCSI device class: DEC SIM
Bus Number: 0
Target number: 6
Lun Number: 0
Name of routine that logged the event: ss_abort_done
Event information: SCSI abort has been performed
======================================================================