• 软件测试技术
  • 软件测试博客
  • 软件测试视频
  • 开源软件测试技术
  • 软件测试论坛
  • 软件测试沙龙
  • 软件测试资料下载
  • 软件测试杂志
  • 软件测试人才招聘
    暂时没有公告

字号: | 推荐给好友 上一篇 | 下一篇

RFC387 - Some experiences in implementing Network Graphics Protocol Level 0

发布: 2007-6-23 14:09 | 作者:   | 来源:   | 查看: 13次 | 进入软件测试论坛讨论

领测软件测试网

   
  Network Working Group Karl C. Kelley
Request for Comments: 387 Jaacov Meir
NIC: 11359 8/10/72
Categories: D.6, F
Obsoletes:
References: RFC#292

SOME EXPERIENCES IN IMPLEMENTING NETWORK GRAPHICS PROTOCOL LEVEL 0


We are in the process of implementing NGP-0 at several hosts. For
the time being, we are forced to consider the remote host as the "last
intelligent machine". We are attempting to translate NGP-0 to a machine
dependent code for the Computek display. The remote hosts are CCN, UCSD,
and soon RANDCSG. More comments about that work will be made in
subsequent RFC's. The concern of this RFCis twofold:

1. Clarify the coordinate number system.

2. Puzzle over how to do TEXTR string without either:

a. Reading current position and saving it while the text string
is being output, or

b. Monitoring the beam position for each NGP command and saving
this information somewhere.

An appendix to this RFCwill outline the conversion from the NGP
coordinate system to the floating point arithmetic on the PDP-1O.

The Coordinate Data

The document for NGP-0 (RFC292) does not say specifically that the
format of coordinate data is the same whether the command is in absolute
or relative mode. The only thing stated is that they are in two's
complement notation with the leftmost bit being the sign bit. It is
possible to use two different 2's complement schemes:

System A System B
(Absolute Coordinates) (Relative Coordinates)

-1 -2 -3 -16 0 -1 -2 -15
-2 2 2 ... ...2 -2 2 2 ... 2
+--+--+--+--+---------+--+--+ +--+--+--+--+---------+--+--+
| | | | | | | | | | | | | | | |
+--+--+--+--+---------+--+--+ +--+--+--+--+---------+--+--+
^ ^

.0111 ...............11 = +1/2-e 0.11 ..............11 = 1-e

.00 .................01 = +e 0.100 .............00 = 1/2

.00 .................0 = 0 0.00...............01 = e

.111 ................11 = -e 0.00 ..............00 = 0

.100 ................ = 1/2 1.11 ..............11 = -e

1.10 ..............00 = -1/2

1.00 ..............01 = -1+e = -(1-e)

1.00 ..............00 = -1

-16 -15
Where: e = 2 Where: e = 2

-16 -15
Range: -1/2 to +1/2 - 2 Range: -1 to +1 - 2

I submit that one could interpret the requirement for absolute
coordinate data to be in the range -1/2 to +1/2 - e as requiring that
two different number systems should be used. Thinking along those
lines, System A has the advantage that you never get handed a number out
of range, which saves some checking worries. It also has one whole bit
more of precision.

I further submit that having two systems to contend with merely
clouds the issue and requires extra coding. It makes more sense just to
stick with System B above. Among the advantages in its use are:

1. The single system can handle both absolute and relative
coordinates.

2. If an absolute coordinate exceeds range, simply forcing the sign
bit on causes a nice wrap-around.

3. The representation is the same as the mantissa for floating
point numbers on most machines. Notice, however, that mantissas
of normalized floating point numbers are not in the range for
absolute coordinates. The program will have to shift the
mantissa until exponent is 0.

It may be that few of us interpreted the NGP document to mean two
number systems were needed. If that is the case, so much the better.
In any case, until shaken from the position by the overwhelming force of
contrary logic, we will, in all of our implementations, use System B
above for both absolute and relative coordinates.

The TEXTR Command
-----------------

The last paragraph on page 4 of RFC292 says, "...a command be
included only if its output is a function solely of the current command
and the "beam position" current at the start of the command. In other
words, the interpreter for level 0 need have no internal storage for
'modes' or pushdown stacks."

In the case of the Computek display, most of the NGP commands
correspond to capabilities of the device. The lone exception is the
TEXTR command. There are two ways to know what beam position to return
to after the string is displayed. One way is to read the cursor position
from the display just before doing the string output. This is no good
because it requires reading from the device (which we can't do until
input protocols are implemented). Also, on this device, the cursor
position is accurate only to within 4 scope points.

The second way to know what beam position to return to is to monitor
all motions of the beam in software. Thus our implementations of NGP-0
to Computek translations will employ a software X register and Y
register. On absolute commands, the registers will be set to the
coordinates for that command. On relative commands, the coordinate data
will be added to the registers. At the beginning and end of picture,
these registers will be set to 0.

The TEXTR command will also cause these software beam registers to
be changed. That is, the X register will be incremented for each
character of the string to correspond to what is happening in the
display itself.

APPENDIX

NGP-0 to PDP-10 Floating Point
------------------------------

The NGP-0 looks at all data numbers (X and Y parameters) as a
fraction number in the following format (16 bits per number).

+--+--+--+--+--+--+-----------------+--+--+--+--+
| | | | | | | ... ... | | | | |
+--.--+--+--+--+--+-----------------+--+--+--+--+
Bit position 0 1 2 3 ...... 14 15

with the binary point assumed between bits 0 and 1. Bit 0 is the sign
bit and all negative numbers are represented as their two's complement.
The PDP-10 machine code representation of fractions in floating point
(mantissa part) is very similar to the above (with one exception--the
number -1), so the transformation could be obtained simply by two
operations, move and substitute.

Data (X,Y) Conversion
---------------------

NGP (extreme points) Floating Point (PDP-10)

(16 bits) (36 bits)
exp mantissa

1/2 0.1000 . . . . . .0 0 10000000 10 . . . . . .0

-1/2 1.1000 . . . . . .0 1 01111111 10 . . . . . .0

-1 1.00 . . . . . .0 1 01111101 10 . . . . . .0
Special case

1-e 0.11 . . . . . .1 0 10000000 1111 . . . . .1

Translation from NGP into floating point for PDP-1O:

1. Move sign bit (leftmost one) to sign bit.

2. Move fraction part (15 bits) to mantissa part (left justified;
fill with zero's to right).

3. Fill in exponent part (8 bits) according to:

a. If positive number exp = 10000000 = (80) hex

b. If negative number exp = 01111111 = (7F) hex

c. Exception _in_only_ one number

-1 in NGP (negative sign and fraction all zero's)

(1) mantissa becomes same as -1/2

(2) exponent becomes the one's complement of (82) hex
= (7D) hex

The methods of conversion will remain the same regardless of the
number of bits (up to 24) that are used for the NGP fraction.

[ This RFCwas put into machine readable form for entry ]
[ into the online RFCarchives by Alex McKenzie with ]
[ support from GTE, formerly BBN Corp. 9/99 ]

延伸阅读

文章来源于领测软件测试网 https://www.ltesting.net/


关于领测软件测试网 | 领测软件测试网合作伙伴 | 广告服务 | 投稿指南 | 联系我们 | 网站地图 | 友情链接
版权所有(C) 2003-2010 TestAge(领测软件测试网)|领测国际科技(北京)有限公司|软件测试工程师培训网 All Rights Reserved
北京市海淀区中关村南大街9号北京理工科技大厦1402室 京ICP备2023014753号-2
技术支持和业务联系:info@testage.com.cn 电话:010-51297073

软件测试 | 领测国际ISTQBISTQB官网TMMiTMMi认证国际软件测试工程师认证领测软件测试网