在一个通道上做了一个raid组,造成performance不高,且危险性太高
:
//以下文档为重新移动raid组(保留数据)的磁盘的说明文档
//仅供参考,在操作当中应小心使用各条命令。
HSZ> show this full
Controller:
HSZ50-AX ZG72431511 Firmware V51Z-0, Hardware A01
Configured for dual-redundancy with ZG72330202
In dual-redundant configuration
SCSI address 7
Time: NOT SET
Host port:
SCSI target(s) (0, 1, 2, 3), Preferred target(s) (0, 1, 2, 3)
TRANSFER_RATE_REQUESTED = 10MHZ
Cache:
64 megabyte write cache, version 3
Cache is GOOD
Battery is GOOD
Unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
CACHE_POLICY = A
NOCACHE_UPS
Host Functionality Mode = A
Licensing information:
RAID (RAID Option) is ENABLED, license key is VALID
WBCA (Writeback Cache Option) is ENABLED, license key is VALID
MIRR (Disk Mirroring Option) is ENABLED, license key is VALID
Extended information:
Terminal speed 9600 baud, eight bit, no parity, 1 stop bit
Operation control: 00000004 Security state code: 85810
Configuration backup disabled
HSZ> show other full
Controller:
HSZ50-AX ZG72330202 Firmware V51Z-0, Hardware A01
Configured for dual-redundancy with ZG72431511
In dual-redundant configuration
SCSI address 6
Time: NOT SET
Host port:
SCSI target(s) (0, 1, 2, 3), No preferred targets
TRANSFER_RATE_REQUESTED = 10MHZ
Cache:
64 megabyte write cache, version 3
Cache is GOOD
Battery is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
CACHE_POLICY = A
NOCACHE_UPS
Host Functionality Mode = A
Licensing information:
RAID (RAID Option) is ENABLED, license key is VALID
WBCA (Writeback Cache Option) is ENABLED, license key is VALID
MIRR (Disk Mirroring Option) is ENABLED, license key is VALID
Extended information:
Terminal speed 9600 baud, eight bit, no parity, 1 stop bit
Operation control: 00000004 Security state code: 91931
Configuration backup disabled
HSZ> show r1
Name Storageset Uses Used by
------------------------------------------------------------------------------
R1 raidset DISK100 D0
DISK110
DISK200
DISK210
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
NORMAL
DISK100 (member 0) is NORMAL
DISK110 (member 1) is NORMAL
DISK200 (member 2) is NORMAL
DISK210 (member 3) is NORMAL
Size: 25127937 blocks
HSZ> show d0
LUN Uses
--------------------------------------------------------------
D0 R1
Switches:
RUN NOWRITE_PROTECT READ_CACHE
NOWRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 25127937 blocks
HSZ> show r2
Name Storageset Uses Used by
------------------------------------------------------------------------------
R2 raidset DISK120 D100
DISK130
DISK220
DISK230
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
NORMAL
DISK120 (member 0) is NORMAL
DISK130 (member 1) is NORMAL
DISK220 (member 2) is NORMAL
DISK230 (member 3) is NORMAL
Size: 25127937 blocks
HSZ> show d100
LUN Uses
--------------------------------------------------------------
D100 R2
Switches:
RUN NOWRITE_PROTECT READ_CACHE
NOWRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 25127937 blocks
HSZ> show r3
Name Storageset Uses Used by
------------------------------------------------------------------------------
R3 raidset DISK300 D200
DISK310
DISK320
DISK330
DISK340
DISK350
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
NORMAL
DISK300 (member 0) is NORMAL
DISK310 (member 1) is NORMAL
DISK320 (member 2) is NORMAL
DISK330 (member 3) is NORMAL
DISK340 (member 4) is NORMAL
DISK350 (member 5) is NORMAL
Size: 88824180 blocks
HSZ> show d200
LUN Uses
--------------------------------------------------------------
D200 R3
Switches:
RUN NOWRITE_PROTECT READ_CACHE
NOWRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
State:
ONLINE to this controller
Reserved
PREFERRED_PATH = THIS_CONTROLLER
Size: 88824180 blocks
HSZ>
/**************以上为检查相关信息,以便在移动后进行检查*****************/
/******下面是移动的具体步聚******/
/********step 1: 删除所有相关的unit,storageset,disk*********/
1. delete d200c
2. delete r3
3. delete disk300 disk310 disk320 disk330 disk340 disk350
4. delete d100
5. delete r2
delete disk120
delete disk130
delete disk220
delete disk230
/********step 1: 完毕*********/
/********step 2: 物理上移动disk的位置******/
disk300,disk310 no move
disk320<-->disk120 disk330<-->disk130
disk340 --> disk240 disk350 --> disk250
/********step 2: 移动完毕,检查各指示灯是否正确******/
/********step 3: 加入新的disk,raid,unit ******/
6. add disk disk300 3 0 0
add disk disk310 3 1 0
add disk disk120 1 2 0
add disk disk130 1 3 0
add disk disk240 2 4 0
add disk disk250 2 5 0
add raid r3 disk300 disk310 disk120 disk130 disk240 disk250
add unit d200 r3
7. add disk disk220 2 2 0
add disk disk230 2 3 0
add disk disk320 3 2 0
add disk disk330 3 3 0
add raid r2 disk220 disk230 disk320 disk330
add unit d100 r2
/********step 3: 加入完毕 ******/
/********step 4: 重启并检查是否正确,并联上主机,进行检测********/
8. restart other
restart this
9. show d0
show d100
show d200
//检查配置是否正确
//以上调整在洛阳通信公司成功通过
//相信在其他型号的控制器上也可以成功,请大家查阅一下即可,应该没有问题
//不过,一定要用户做好数据备份
//see also Page 200-- 209 (EK-HSZ50-SV-C01.pdf in L100 cdrom)
//if you have any question or trouble, i suggest you call Cade yang, He's a master of this field...
netkey 回复于:2003-02-12 00:17:51 |
已经改名字加精华了 |
david5337 回复于:2003-02-12 12:29:55 |
[quote:40a8c022b8="netkey"]已经改名字加精华了[/quote:40a8c022b8]呵呵!其实上面的操作就是对DEC的磁盘柜操作,只要大家看一下DEC提供的安装文档就可以了!没有什么实质性的意义!
但是,上面所指出的性能问题,要大家引起足够的重视,一个RAID的中硬盘最好是分布在几个不同的通道上,可以提高读写性能。 大家可以找我多交流存储技术! |
stone0525 回复于:2003-04-02 16:14:41 |
同意楼上,我还以为不用重新导数据的做法哪。这不重新配置吗 |
我爱小笼包 回复于:2003-05-21 14:08:14 |
1. 这个就是不用重新导数据呀,上面说要备份好数据只是以防万一。因为重建后的raid组没有用init进行初始化,如初始化了就完了。
2. 做完后,重新启动主机,就可以像原来一样用,不用改动任何东东了。 3. 另外下面每个加disk,storageset等都可以起不同的名字,只要unit不变就行了。不过请注意如果有partition的话要更加小心千万不能错。 4. 此方法也可以用于把所有的盘换到另一个盘柜上去。 |
superlikai 回复于:2003-07-24 21:31:09 |
有compaq MA8000的相关操作文档吗 |
延伸阅读
文章来源于领测软件测试网 https://www.ltesting.net/