下一页 1 2
本来是看一个题目觉得奇怪的,于是去查CISCO 文档,结果发现那个题目就是CISCO 文档上的东西. 只是这个文档本来是发布IOS bug的一个通告,下面是关键内容. Loopback Test: Test for a spanning-tree BPDU error. A crossover cable should be connected between two unused access ports. In this case, FastEthernet0/1 and FastEthernet0/2 are configured as access ports and are connected by a crossover cable. See RJ-45 Cables for information on Ethernet RJ-45 crossover pinouts. The interface configuration is shown below: If, after 30 seconds, one of the port LEDs turns amber and the other stays green, the switch is working correctly, either because it does not have the problem or already has the Cisco IOS software upgrade that corrects the problem. If, after 30 seconds, both of the LEDs turn green and flash rapidly, the Cisco IOS software will need to be upgraded. This can also be verified by looking at the output from the following commands. If the switch is working correctly, the number of BPDUs received on the blocked port will be a non-zero number and will increase every two seconds, using the default timersSwitch#show run interface FastEthernet0/1
Building configuration...
Current configuration : 72 bytes
!
interface FastEthernet0/1
switchport mode access
no ip address
end
Switch#show run interface FastEthernet0/2
Building configuration...
Current configuration : 72 bytes
!
interface FastEthernet0/2
switchport mode access
no ip address
end
WORKING_Switch#show spanning-tree interface FastEthernet 0/1 detail
Port 1 (FastEthernet0/1) of VLAN0001 is forwarding
Port path cost 19, Port priority 128, Port Identifier 128.1.
Designated root has priority 32769, address 000a.4107.7400
Designated bridge has priority 32769, address 000a.4107.7400
Designated port id is 128.1, designated path cost 0
Timers: message age 0, forward delay 0, hold 0
Number of transitions to forwarding state: 1
BPDU: sent 237, received 1
^^^^^^^^^^^^^^^^^^^^^^^^^^ Port is forwarding and sending BPDUs correctly.
WORKING_Switch#show spanning-tree interface FastEthernet 0/2 detail
文章来源于领测软件测试网 https://www.ltesting.net/
版权所有(C) 2003-2010 TestAge(领测软件测试网)|领测国际科技(北京)有限公司|软件测试工程师培训网 All Rights Reserved
北京市海淀区中关村南大街9号北京理工科技大厦1402室 京ICP备10010545号-5